{"id":3278,"date":"2013-11-26T15:46:59","date_gmt":"2013-11-26T14:46:59","guid":{"rendered":"https:\/\/www.mauritz.de\/blog\/?p=3278"},"modified":"2015-12-14T22:54:07","modified_gmt":"2015-12-14T20:54:07","slug":"clf200-contra-aircell5","status":"publish","type":"post","link":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/","title":{"rendered":"CLF200 Low Loss contra Aircell 5"},"content":{"rendered":"<div id=\"attachment_3289\" style=\"width: 310px\" class=\"wp-caption alignright\"><img aria-describedby=\"caption-attachment-3289\" decoding=\"async\" class=\"size-medium wp-image-3289\" src=\"https:\/\/www.mauritz.de\/blog\/wp-content\/uploads\/2013\/11\/CLF200-Aircell5-300x300.jpg\" alt=\"CLF200 - Aircell 5 - Gegen\u00fcberstellung\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.mauritz.de\/blog\/wp-content\/uploads\/2013\/11\/CLF200-Aircell5-300x300.jpg 300w, https:\/\/www.mauritz.de\/blog\/wp-content\/uploads\/2013\/11\/CLF200-Aircell5-150x150.jpg 150w, https:\/\/www.mauritz.de\/blog\/wp-content\/uploads\/2013\/11\/CLF200-Aircell5.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-3289\" class=\"wp-caption-text\">CLF200 &#8211; Aircell 5 &#8211; Gegen\u00fcberstellung<\/p><\/div>\n<h2>CLF200 Low Loss oder Aircell 5 ?<\/h2>\n<p>Ein interessanter Bericht \u00fcber unsere Erfahrungen mit den sehr \u00e4hnlichen Koaxialkabeln <strong>CLF200 Low Loss<\/strong> und <strong>Aircell 5<\/strong>.<\/p>\n<p>In erster Instanz zeichnet sich das <a title=\"Koaxialkabel\" href=\"http:\/\/www.mauritz.de\/de\/koaxialkabel\">Koaxialkabel<\/a> <a title=\"Koaxialkabel CLF200 Low Loss\" href=\"http:\/\/www.mauritz.de\/de\/koaxialkabel\/koaxialkabel-50-ohm\/clf-200-koaxialkabel-50-ohm\"><strong>CLF200 LOW LOSS<\/strong><\/a> 50 Ohm durch seine doppelte Schirmung und geringe D\u00e4mpfung aus. Dies gilt auch im wesentlichen f\u00fcr das Koaxkabel <a title=\"Koaxialkabel Aircell5\" href=\"http:\/\/www.mauritz.de\/de\/koaxialkabel\/koaxialkabel-50-ohm\/aircell-5-koaxialkabel-50-ohm\"><strong>Aircell5<\/strong><\/a>, bei dem die D\u00e4mpfung nur minimale Verluste aufzeigt.<\/p>\n<p>Zudem werden beim <strong>CLF200<\/strong> Hochfrequenzkabel durch seine doppelte Schirmung bessere, technische Werte erzielt, da es einerseits \u00fcber eine beschichtete Aluminiumfolie verf\u00fcgt, die das Dielektrikum umschlie\u00dft, aber auch \u00fcber ein verzinntes Kupfergeflecht. Der Innenleiter besteht aus einem 1,12mm massiven Kupferdraht, der auf Grund des Kabeldurchmessers von 4,95mm relativ flexibel zu verarbeiten bzw. zu verlegen ist.<br \/>\nAus diesem Grund ist es f\u00fcr den Bereich bis 6 GHz zugelassen, kann aber bedenkenlos bis 39 GHz eingesetzt werden.<br \/>\n<!--more--><br \/>\nBeim <strong>Aircell 5<\/strong> hingegen besteht der Innenleiter aus einem 1,08mm massiven Kupferdraht, der von einem Dielektrikum umgeben ist, das zwar einen hohen Sauerstoffanteil enth\u00e4lt, aber nicht so hoch wie beim <strong>CLF200<\/strong> ist.<br \/>\nDas Dielektrikum wird beim<strong> Aircell5<\/strong> von einer reinen Kupferfolie umschlossen und das Au\u00dfengeflecht besteht lediglich aus Kupfer, dass allerdings nicht die gleiche Dichte besitzt, wie beim <strong>CLF200<\/strong>, sodass dass vergleichbar hohe Schirmungsma\u00df und die hohe R\u00fcckflussd\u00e4mpfung beim <strong>CLF200<\/strong> dem deutlich dichteren Au\u00dfengeflecht zu verdanken ist. Die vergleichbar geringe D\u00e4mpfung des <strong>CLF 200<\/strong> wird durch den etwas dickeren Innenleiter aus massivem Kupfer erreicht.<\/p>\n<p>Die Flexibilit\u00e4t beim <strong>CLF200<\/strong> l\u00e4sst sich beim Biegeradius erkennen, der mit 1,3cm klar dem <strong>Aircell 5<\/strong> gegen\u00fcber \u00fcberlegen ist, welches lediglich mit 2,5cm Biegeradius punkten kann.<\/p>\n<p>Zudem bedingt durch das harmonisch, pr\u00e4zise Zusammenspiel der guten Leitf\u00e4higkeiten von Innen- und Au\u00dfenleiter des <strong>CLF200<\/strong>, sind die Toleranzen und Schwankungen \u00fcber den Frequenzbereich bis 6 GHz von Impedanz, D\u00e4mpfung und R\u00fcckflussd\u00e4mpfung wesentlich ausgewogener als beim Koaxialkabel Aircell 5.<\/p>\n<p>Der schwarze, UV-stabilisierte Kabelmantel des <strong>CLF200<\/strong> ist f\u00fcr einen Temperaturbereich von -40\u00b0C bis +85\u00b0C ausgelegt.<br \/>\nHinsichtlich des Temperaturbereiches ist das <strong>CLF200<\/strong> dem <strong>Aircell5<\/strong> geringf\u00fcgig bei den Minustemperaturen unterlegen, da dieses Kabel nach Herstellerangabe bis -55\u00b0C einsetzbar ist.<\/p>\n<p>Diverse HF Steckverbinder f\u00fcr <strong>CLF200<\/strong> und <strong>Aircell5<\/strong> wie z.B. BNC, FME, N, SMA, SMB, TNC, UHF, RP BNC, RP N, RP SMA sowie RP TNC in Crimp- und teilweise auch in Clamp-Ausf\u00fchrung werden f\u00fcr diese beiden Kabel speziell empfohlen.<\/p>\n<p>Vergleicht man die geringen D\u00e4mpfungsunterschiede von<strong> CLF200<\/strong> und <strong>Aircell 5<\/strong>, sind die Unterschiede beider Koaxialkabel f\u00fcr den Einsatz in der Praxis so minimal, dass die Entscheidung f\u00fcr das preiswertere Kabel <strong>CLF200<\/strong> sehr leicht fallen sollte.<\/p>\n<h2>Kurz\u00fcbersicht<\/h2>\n<table border=\"0\" width=\"700\" cellspacing=\"3\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td><\/td>\n<td>\n<h2 align=\"center\">CLF200<\/h2>\n<\/td>\n<td>\n<h2 align=\"center\">Aircell 5<\/h2>\n<\/td>\n<\/tr>\n<tr>\n<td>Impedanz<\/td>\n<td>\n<div align=\"center\">50 OHM<\/div>\n<\/td>\n<td>\n<div align=\"center\">50 OHM<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Innenleiter \u00d8<\/td>\n<td>\n<div align=\"center\">1,12mm<\/div>\n<\/td>\n<td>\n<div align=\"center\">1,08mm<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Innenleiter<\/td>\n<td style=\"text-align: center;\">\u00a0CU massiv<\/td>\n<td style=\"text-align: center;\">\u00a0CU massiv<\/td>\n<\/tr>\n<tr>\n<td>Dielektrikum\u00a0\u00d8<\/td>\n<td>\n<div align=\"center\">2,95mm<\/div>\n<\/td>\n<td>\n<div align=\"center\">\u00a02,95mm<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Au\u00dfenleiter 1<\/td>\n<td>\n<div align=\"center\">Alufolie \/ PE beschichtet<\/div>\n<\/td>\n<td>\n<div align=\"center\">Kupferfolie \/ PE beschichtet<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Au\u00dfenleiter 2<\/td>\n<td>\n<div align=\"center\">Kupfergeflecht verzinnt<\/div>\n<\/td>\n<td>\n<div align=\"center\">Kupfergeflecht<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Au\u00dfenmantel<\/td>\n<td>\n<div align=\"center\">PVC schwarz \/ UV-stabil<\/div>\n<\/td>\n<td>\n<div align=\"center\">PVC schwarz \u00a0\/ UV-stabil<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Au\u00dfenmantel \u00d8<\/td>\n<td>\n<div align=\"center\">4,95mm<\/div>\n<\/td>\n<td>\n<div align=\"center\">5,00mm<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Biegeradius<\/td>\n<td>\n<div align=\"center\">1,3cm<\/div>\n<\/td>\n<td>\n<div align=\"center\">2,5cm<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Gewicht<\/td>\n<td>\n<div align=\"center\">\u00a037g\/m<\/div>\n<\/td>\n<td>\n<div align=\"center\">\u00a036g\/m<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Temperaturbereich<\/td>\n<td>\n<div align=\"center\">-40\u00b0C bis +85\u00b0C<\/div>\n<\/td>\n<td>\n<div align=\"center\">-55\u00b0C bis + 85\u00b0C<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Grenzfrequenz<\/td>\n<td>\n<div align=\"center\">39GHz<\/div>\n<\/td>\n<td>\n<div align=\"center\">33GHz<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>D\u00e4mpfung @ 1 GHz \/100m<\/td>\n<td>\n<div align=\"center\">33,3 dB<\/div>\n<\/td>\n<td>\n<div align=\"center\">31,9 dB<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>CLF200 Low Loss oder Aircell 5 ? Ein interessanter Bericht \u00fcber unsere Erfahrungen mit den sehr \u00e4hnlichen Koaxialkabeln CLF200 Low Loss und Aircell 5. In erster Instanz zeichnet sich das Koaxialkabel CLF200 LOW LOSS 50 Ohm durch seine doppelte Schirmung &hellip; <a href=\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/\">Weiterlesen <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[541,62,83,11,1],"tags":[97,103,725,940,882,821,918,881,875,729,886,883,888,166,924,887,891,890,889,432,876],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.12 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>CLF200 Low Loss und Aircell 5 - Koaxialkabel Gegen\u00fcberstellung<\/title>\n<meta name=\"description\" content=\"CLF200 Low Loss und Aircell 5, \u00e4hnliche Koaxialkabel in der technischen Gegen\u00fcberstellung - Aufbau, Durchmesser, Frequenz, D\u00e4mpfung, Biegeradius, UV-stabili\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gerhard Mauritz\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/\",\"url\":\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/\",\"name\":\"CLF200 Low Loss und Aircell 5 - Koaxialkabel Gegen\u00fcberstellung\",\"isPartOf\":{\"@id\":\"https:\/\/www.mauritz.de\/blog\/#website\"},\"datePublished\":\"2013-11-26T14:46:59+00:00\",\"dateModified\":\"2015-12-14T20:54:07+00:00\",\"author\":{\"@id\":\"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/bf9f1de5199065840478999bc949484a\"},\"description\":\"CLF200 Low Loss und Aircell 5, \u00e4hnliche Koaxialkabel in der technischen Gegen\u00fcberstellung - Aufbau, Durchmesser, Frequenz, D\u00e4mpfung, Biegeradius, UV-stabili\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.mauritz.de\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"CLF200 Low Loss contra Aircell 5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mauritz.de\/blog\/#website\",\"url\":\"https:\/\/www.mauritz.de\/blog\/\",\"name\":\"Mauritz\",\"description\":\"Kabelkonfektion Steckverbinder Schrumpfschlauch Kabelbinder\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mauritz.de\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/bf9f1de5199065840478999bc949484a\",\"name\":\"Gerhard Mauritz\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.mauritz.de\/blog\/wp-content\/litespeed\/avatar\/ac454cb4bb35cfc949ba11db959d3857.jpg?ver=1777933747\",\"contentUrl\":\"https:\/\/www.mauritz.de\/blog\/wp-content\/litespeed\/avatar\/ac454cb4bb35cfc949ba11db959d3857.jpg?ver=1777933747\",\"caption\":\"Gerhard Mauritz\"},\"sameAs\":[\"http:\/\/www.mauritz.de\/blog\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CLF200 Low Loss und Aircell 5 - Koaxialkabel Gegen\u00fcberstellung","description":"CLF200 Low Loss und Aircell 5, \u00e4hnliche Koaxialkabel in der technischen Gegen\u00fcberstellung - Aufbau, Durchmesser, Frequenz, D\u00e4mpfung, Biegeradius, UV-stabili","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/","twitter_misc":{"Verfasst von":"Gerhard Mauritz","Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/","url":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/","name":"CLF200 Low Loss und Aircell 5 - Koaxialkabel Gegen\u00fcberstellung","isPartOf":{"@id":"https:\/\/www.mauritz.de\/blog\/#website"},"datePublished":"2013-11-26T14:46:59+00:00","dateModified":"2015-12-14T20:54:07+00:00","author":{"@id":"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/bf9f1de5199065840478999bc949484a"},"description":"CLF200 Low Loss und Aircell 5, \u00e4hnliche Koaxialkabel in der technischen Gegen\u00fcberstellung - Aufbau, Durchmesser, Frequenz, D\u00e4mpfung, Biegeradius, UV-stabili","breadcrumb":{"@id":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mauritz.de\/blog\/clf200-contra-aircell5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.mauritz.de\/blog\/"},{"@type":"ListItem","position":2,"name":"CLF200 Low Loss contra Aircell 5"}]},{"@type":"WebSite","@id":"https:\/\/www.mauritz.de\/blog\/#website","url":"https:\/\/www.mauritz.de\/blog\/","name":"Mauritz","description":"Kabelkonfektion Steckverbinder Schrumpfschlauch Kabelbinder","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mauritz.de\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/bf9f1de5199065840478999bc949484a","name":"Gerhard Mauritz","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.mauritz.de\/blog\/#\/schema\/person\/image\/","url":"https:\/\/www.mauritz.de\/blog\/wp-content\/litespeed\/avatar\/ac454cb4bb35cfc949ba11db959d3857.jpg?ver=1777933747","contentUrl":"https:\/\/www.mauritz.de\/blog\/wp-content\/litespeed\/avatar\/ac454cb4bb35cfc949ba11db959d3857.jpg?ver=1777933747","caption":"Gerhard Mauritz"},"sameAs":["http:\/\/www.mauritz.de\/blog\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/posts\/3278"}],"collection":[{"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/comments?post=3278"}],"version-history":[{"count":50,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/posts\/3278\/revisions"}],"predecessor-version":[{"id":3350,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/posts\/3278\/revisions\/3350"}],"wp:attachment":[{"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/media?parent=3278"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/categories?post=3278"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mauritz.de\/blog\/wp-json\/wp\/v2\/tags?post=3278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}